2Gbps

Expansion link indicator

Host 1

Host 2

 

 

 

 

10BT

100BT

2Gb/s

2Gb/s

 

 

Host 1

Host 2

10BT

100BT

indicator

indicator

 

 

Figure 58. RAID controller LEDs

Table 13. RAID controller LEDs

Icon

LED

Color

 

 

 

Fault

Amber

 

 

 

 

 

 

 

 

Host loop

Green

Cache active Green

+

 

 

Battery

Green

 

 

Expansion

10101

+

 

 

 

f10ug025

charging

active

fault

by-pass

Battery

Cache

Controller

Expansion

 

Operating states1

vOff - Normal operation.

vOn - One of the following situations has occurred:

The RAID controller has failed.

The RAID controller was placed offline

The controller battery had failed (in conjunction with the battery LED in off state).

vOn - Normal operation.

vOff - One of the following situations has occurred:

The host loop is down, not turned on, or not connected.

A SFP has failed, or the host port is not occupied.

The RAID controller circuitry has failed, or the RAID controller has no power.

vOn - There is data in the RAID controller cache.

vOff - One of the following situations has occurred:

There is no data in cache.

There are no cache options selected for this array.

The cache memory has failed, or the battery has failed.

vOn - Normal operation.

vFlashing - The battery is recharging or performing a self-test.

vOff - The battery or battery charger has failed.

Chapter 4. Operating the storage server 73