DS4100 specifications

Table 9 lists the physical specifications for the DS4100.

Table 9. IBM TotalStorage DS4100 specifications

Size

vWidth: 48.18 cm (18.97 in.)

vHeight: 13.23 cm (5.21 in.)

vDepth: 59.74 cm (23.52 in.)

Weight

vDrive-ready weight (without disk drive modules installed):

Model 100: 26.64 kg (58.9 lb)

Model 1Sx: 23.44 kg (51.9 lb)

vFully configured weight (with 14 disk drives installed):

Model 100: 40.36 kg (89 lb)

Model 1Sx: 37.16 kg (82 lb)

Environment

vAir temperature

Operating:

-Altitude: 0 - 914 m (3000 ft): 10° - 35° C (50° - 95° F)

-Altitude: 914 m - 2133 m (3000 -

7000 ft): 10° - 32° C (50° - 90° F)

Important: The recommended operating environment air temperature is 22° C (72° F) or lower.

Storage:

-Altitude: 0 - 914 m (3000 ft): 1° - 60° C (33° - 140° F)

-Altitude: 914 m - 2133 m (3000 -

7000 ft): 1° - 57° C (33° - 135° F) v Humidity

8% - 80%

Noncondensing

Heat dissipation

vFully configured storage server (14 1.5 Gbps SATA hard disk drives)

– 1235 BTU per hour

Acoustical noise emission values

For open bay (0 drives installed) and typical system configurations (eight hard disk drives installed):

vSound power (idling):

5.9 bel (open bay)

6.1 bel (typical)

vSound power (operating):

5.9 bel (open bay)

6.2 bel (typical)

vSound pressure (idling):

44 dBA (open bay)

46 dBA (typical)

vSound pressure (operating):

44 dBA (open bay)

47 dBA (typical)

These levels are measured in controlled acoustical environments according to ISO 7779 and are reported in accordance with ISO 9296. The declared sound power levels indicate an upper limit, below which a large portion of machines operate. Sound pressure levels in your location might exceed the average 1-meter values stated because of room reflections and other nearby noise.

Notes:

1.The nonoperating environment must not exceed the operating environment limits for longer than 60 days.

2.The storage environment must not exceed the operating environment limits for longer than 1 year.

3.Substantial deviations from the suggested operating range, in either direction, if sustained for extended periods of time, will expose the unit to greater risk of failure from external causes.

The AC power sources must provide the correct voltage, current, and frequency specified on the storage server. The storage server can run without interruption within the limits shown in Table 10 on page 15.

14IBM TotalStorage DS4100 Storage Server: Installation, User’s, and Maintenance Guide

Page 46
Image 46