Front of Rack

f10ug051

Figure 17. Installing the DS4100

2.The bezel is secured to the front of the DS4100 either by plastic wingnuts or by adhesive tape. Remove and discard the wingnuts or the adhesive tape. The bezel should remain attached to the DS4100 chassis.

Attention: The bottom cross member of the bezel has a tab that must fit beneath the DS4100 chassis and snap into place. The top cross member of the bezel has a recess that must be mated with a metal tab on the bottom of the DS4100 chassis.

3.Secure the DS4100 to the rack cabinet:

a.Align the front mounting holes on each side of the storage server with the mounting holes on the front of the support rails.

b.Install the bezel.

c.Insert an M6 screw into the mounting hole on both sides of the front of the unit (see Figure 9 on page 21). Gently tighten the screws to secure the bezel and the front of the DS4100 to both of the front cabinet rails.

Attention: Do not overtighten. If you overtighten these screws, you could break the bezel.

d. From the back of the rack cabinet, insert the two 6/32 in. screws ( in Figure 12 on page 24), one on each side, in the holes located on the tab on each side of the unit. Tighten the screws.

4.Continue with one of the following actions:

v If you did remove the DS4100 CRUs before installation (as described in “Removing the CRUs” on page 25), continue with “Replacing the DS4100 CRUs.”

vIf you did not find it necessary to remove the DS4100 CRUs before installation, continue with “Setting the interface options” on page 32.

Replacing the DS4100 CRUs

Use the following procedures to replace the CRUs in the DS4100 after installation.

Chapter 2. Installing the storage server 29

Page 61
Image 61
IBM Partner Pavilion manual Replacing the DS4100 CRUs, Installing the DS4100