1.Push down on the latch (centered above the RAID controller). Pull both levers at the same time out of the locked position.

f10ug033

Figure 13. Removing a RAID controller

2.Grasp the pull-rings; then pull on the levers and remove the RAID controller.

3.Place the RAID controller on a level surface.

4.For the DS4100 base storage server, repeat step 1 through step 3 for the second RAID controller.

Note: In the DS4100 single-controller storage server, you do not need to remove the controller blank.

Removing a power supply

Complete the following steps to remove a power supply:

1.Grasp the pull-ring on the power supply lever and squeeze the latch to release it.

2.Pull the lever open 90° and remove the power supply, as shown in Figure 14 on page 27.

26IBM TotalStorage DS4100 Storage Server: Installation, User’s, and Maintenance Guide

Page 58
Image 58
IBM Partner Pavilion DS4100 manual Removing a power supply