Replacing a RAID controller

Complete the following steps to replace the RAID controller that you removed before the installation:

f10ug033

Figure 18. Replacing a RAID controller

1.Slide the RAID controller all the way into the empty slot.

2.Close both levers until the latch locks into place.

Attention: Make sure that the levers lock into place in the storage server chassis.

3.For the DS4100 base storage server, repeat step 1 and step 2 to replace the second RAID controller.

Replacing a power supply

Complete the following steps to replace the power supplies that you removed before the installation:

1.Slide one power supply into the storage server. Be sure to replace the power supplies so that the lever on each power supply opens toward the interior of the storage server, as shown in Figure 19 on page 31.

Attention: Be sure that the lever is pulled straight out as you slide the power supply into the storage server, as shown in Figure 19 on page 31.

30IBM TotalStorage DS4100 Storage Server: Installation, User’s, and Maintenance Guide

Page 62
Image 62
IBM Partner Pavilion DS4100 manual Replacing a RAID controller