1. On the end of the cable that connects into the LC connector end of the LC-SC
cable adapter, press down and hold the lever to release the latches. Figure 48
shows the location of the lever and latches.
Lever
Latches
f10ug018
2. Carefully pull on the connector to remove it. Make sure you grasp the connector
and not the cable when removing the LC-LC cable from the LC-SC cable
adapter as shown in Figure 49.
f10ug015

3. Replace the protective caps on the cable ends.

Connecting hosts to the RAID controllers
Complete the procedure that is appropriate to your DS4100 storage server model:
v “Connecting hosts to a DS4100 base storage server” on page 55
v “Connecting hosts to a DS4100 single-controller storage server” on page 56
Connecting hosts to a DS4100 base storage server

To connect a host adapter to the DS4100 base storage server RAID controllers,

perform the following steps:
1. Install an SFP in a host port on the RAID controller.
2. Connect the host-system cables to the RAID controller or to switches. Figure 50
on page 56 shows the location on the RAID controllers where the host-system

cables connect.

Figure 48. LC-LC fibre-channel cable lever and latches

Figure 49. Removing the LC-LC fibre-channel cable from an LC-SC fibre-channel cable

adapter

Chapter 3. Cabling the storage server 55