IBM Partner Pavilion DS4100 manual Hardware maintenance

Models: DS4100

1 180
Download 180 pages 56 Kb
Page 145
Image 145

Table 17. Symptom-to-FRU index (continued)

Problem

 

 

 

indicator

Component

Possible cause

Possible solutions

 

 

 

 

All green LEDs off

All CRUs

Subsystem

Check that all storage-server

 

 

power is off

power cords are plugged in and

 

 

 

the power switches are on. If

 

 

 

applicable, check that the main

 

 

 

circuit breakers for the rack

 

 

 

cabinet are turned on.

 

 

 

 

 

 

AC power failure

Check the main circuit breaker

 

 

 

and ac outlet.

 

 

 

 

 

 

Power supply

Replace the power supply.

 

 

failure

 

 

 

 

 

 

 

Midplane failure

Have the midplane replaced

 

 

 

(service technician only).

 

 

 

 

Amber LED

Drive CRUs

Drive identify is in

No corrective action is needed.

flashing

 

process

 

 

 

 

 

One or more

Power supply

Power cord

Make sure that the power cord is

green LEDs off

CRUs

unplugged or

plugged in and the power-supply

 

 

switches turned

switches are turned on.

 

 

off

 

 

 

 

 

 

All drive CRUs

Midplane failure

Have the midplane replaced

 

 

 

(service technician only).

 

 

 

 

 

Front panel

Power supply

Make sure that the cords are

 

 

problem

plugged in and power supplies

 

 

 

are turned on.

 

 

 

 

 

 

Hardware failure

If any other LEDs are on, replace

 

 

 

the midplane (service technician

 

 

 

only).

 

 

 

 

 

Battery

Battery failure

Replace the battery.

 

 

 

 

 

Cache active

The cache is

Use the DS4000 Storage

 

 

disabled

Manager client to enable the

 

 

 

logical drive read and write cache

 

 

 

settings.

 

 

 

 

 

 

The cache

Replace the RAID controller.

 

 

memory has

 

 

 

failed

 

 

 

 

 

 

 

The cache

Use the DS4000 Storage

 

 

battery has failed

Manager client to check and

 

 

 

replace the battery.

 

 

 

 

 

Host loop

Host or switch is

Check if host or switch is on.

 

 

off or has failed

Replace attached devices that

 

 

 

have failed.

 

 

 

 

 

 

Fibre-channel

Ensure that the fibre-channel

 

 

cable has failed

cables are undamaged and

 

 

 

properly connected.

 

 

 

 

 

 

SFP has failed

Ensure SFP is seated properly;

 

 

 

replace SFP.

 

 

 

 

 

 

RAID controller

Ensure that the unit is powered

 

 

has no power or

on. Replace RAID controller.

 

 

has failed

 

 

 

 

 

Chapter 6. Hardware maintenance 113