Controls, Connectors, Indicators: DN9340E

4. REAR PANEL: DN9340E

 

 

1

 

 

2

3

7

5

4

6

5

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Mains

 

 

Mains inlet unit is auto sensing over the range 100-240V AC.

 

 

inlet socket

 

 

 

 

 

 

 

 

2

 

Ethernet

 

 

2-port Ethernet switch for remote control using Cat-5

 

 

 

 

 

 

 

 

cabling.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3RS-232 serial interface RS-232 serial interface for Solo Tracking System operation in association with MIDAS consoles.

4

Inputs A and B

Analogue – electronically balanced XLR audio input sockets

 

 

Pinouts: Pin 1

Screen

 

 

 

 

Pin 2

Hot

 

 

Pin 3

Cold

Digital – input A supports incoming 96kHz AES/EBU signals. Note that when digital input is selected, input B is inactive.

AES/EBU is 110 Ohms. Sample rate converters (SRCs) support incoming signals at sampling frequencies from 32kHz to 96kHz ± 12.5%, while allowing the unit to operate internally at 48kHz. An SRC bypass facility is available for 48kHz operation, to eliminate the propagation delay through the SRC.

Pinouts: Pin 1 Screen

Pin 2 Data +

Pin 3 Data -

5Analogue Outputs A Electronically balanced XLR audio output plugs and B

Pinouts: Pin 1 Screen

Pin 2 Hot

Pin 3 Cold

6Digital Outputs A and B Digital AES/EBU output for channels A and B. AES/EBU is 110 Ohms.

7

Word clock Input

A word clock input is provided for synchronisation purposes.

 

 

 

11

Page 21
Image 21
Klark Teknik DN9344E specifications Rear Panel DN9340E, Mains, Inputs a and B, Word clock Input