Klark Teknik DN9340E REAR PANEL DN9344E, Controls, Connectors, Indicators DN9344E

Models: DN9344E DN9340E

1 76
Download 76 pages 248 b
Page 57
Image 57
12.REAR PANEL: DN9344E

Controls, Connectors, Indicators: DN9344E

12.REAR PANEL: DN9344E

 

 

1

 

2

 

7

4

3

5

4

3

6

4

3

5

4

3

 

 

 

 

 

 

 

 

 

1

 

Mains inlet socket

 

 

Mains inlet unit is auto sensing over the range 100-240V AC.

2

 

Ethernet

 

 

 

 

2-port Ethernet switch for remote control using Cat-5

 

 

 

 

 

 

 

 

 

cabling.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3Inputs 1A, 1B, 2A and 2B Analogue – electronically balanced XLR audio input sockets

Pinouts: Pin 1 Screen

Pin 2 Hot

Pin 3 Return

Digital – inputs 1A and 2A support incoming 96kHz AES/EBU signals (AES IN 1 and AES IN 2). Note that when digital input is selected, inputs 1B and 2B are inactive.

AES/EBU is 110 Ohms. Sample rate converters (SRCs) support incoming signals at sampling frequencies from 32kHz to 96kHz ±12.5% while allowing the unit to operate internally at 48kHz. An SRC bypass facility is available for 48kHz operation, to eliminate the propagation delay through the SRC.

Pinouts: Pin 1 Screen

Pin 2 Data +

Pin 3 Data -

4Analogue Outputs 1A, Electronically balanced XLR audio output plugs

1B, 2A and 2B

Pinouts: Pin 1 Screen

Pin 2 Hot

Pin 3 Return

5Digital Outputs 1 and 2 Digital AES/EBU output for channels 1A/1B and 2A/2B.

AES/EBU is 110 Ohms.

6

Word clock Input

A word clock input is provided for synchronisation purposes.

 

 

 

7Contact Closure (RELAY) This allows a simple contact closure to recall memories on

interface

the unit. Pin connections are as follows:

 

 

Pin 1 - recall Preset / User 1 on Section 1

(the left-hand unit)

 

Pin 2 - recall Preset / User 2 on Section 1

(the left-hand unit)

 

Pin 3 - recall Preset / User 3 on Section 1

(the left-hand unit)

 

Pin 4 - recall Preset / User 4 on Section 1

(the left-hand unit)

 

Pin 5 - recall Preset / User 1 on Section 2

(the right-hand unit)

 

Pin 6

- recall Preset / User 2 on Section 2

(the right-hand unit)

 

Pin 7

- recall Preset / User 3 on Section 2

(the right-hand unit)

 

Pin 8

- recall Preset / User 4 on Section 2

(the right-hand unit)

 

Pin 9

- common

 

Momentarily connect pin 9 to the appropriate other pin (1-8) to perform a recall.

47

Page 57
Image 57
Klark Teknik DN9340E specifications REAR PANEL DN9344E, Controls, Connectors, Indicators DN9344E