7.7. LCD contrast adjustment (Page 6)

Setup Menu: DN9340E

7.7. LCD contrast adjustment (Page 6)

To ensure optimum screen visibility in a range of lighting conditions, it is possible to individually adjust the contrast of the two LCD displays.

“Alpha” adjusts the contrast of the alphanumeric display

“Graphic” adjusts the contrast of the large graphic display

“INV” allows the mode of the graphic LCD to be switched between white-on-blue to blue-on- white.

7.8. Naming (Pages 7 and 8)

To help with system identification, the DN9340E unit and the current working memory may each be given a name up to 20 characters long.

Both names are shown in the Home page and are retained after power down, which is particularly useful for system reassembly when changing venues.

To enter a name

1Use the left control knob to move the cursor right or left, and the centre control knob to select the letter, number or symbol. (Tip: to clear existing characters enter a blank space which can be found after the letter Z.)

2Press HOME (SETUP) to apply the new name.

All names are stored with System memory settings. The Store function will assume the working memory name as the default memory name, prompting you to edit it if required (see Section 8 Storing and Recalling Settings).

7.9. Delay options (Page 9)

The units of measurement used to specify the delay settings can be set to suit user preference, as follows:

Time (milliseconds and microseconds)

Metric distance (metres)

Imperial distance (feet and inches)

To change the units of measurement

1Turn the left control knob to choose the units.

2For Metric or Imperial distance measurement, specify the ambient temperature of the venue using the centre control knob. The DN9340E will use this to adjust the speed of sound (which varies with temperature) in the delay calculation so that accurate delays are applied to the channels.

The delay units are changed in the input and output menus, with the current values being automatically converted to equivalent values.