To enable the Contact Closure (RELAY) mode

Operation: DN9344E

To enable the Contact Closure (RELAY) mode

1Press and hold the SETUP button to enter the SETUP menu. Note that the red alphanumeric displays are now showing Last Recalled Memory and Communication (COMMS) mode. The blue display mode indicator lights to emphasise this fact. The UP and DOWN buttons illuminate to show that they are now active.

2Use the UP and DOWN buttons to select either “RLP” or “RLU” for preset or user memory recall modes.

Note

The left-hand (Section 1) and right-hand (Section 2) parts of the unit are entirely independent. It is possible to use either RELAY mode on Section 1 while Section 2 is operating in remote control mode, or vice versa. Equally, both sections can operate in either RELAY mode if desired.

3Press SETUP to confirm (unit will display password menu).

4Press SETUP to exit.

Memory recalls are now performed by an external switch or relay that momentarily connects pin 9 of the RELAY connector to one of the other pins.

Function assignments are as follows:

-Pin 1: recall Preset / User 1 on Section 1 (the left-hand unit)

-Pin 2: recall Preset / User 2 on Section 1 (the left-hand unit)

-Pin 3: recall Preset / User 3 on Section 1 (the left-hand unit)

-Pin 4: recall Preset / User 4 on Section 1 (the left-hand unit)

-Pin 5: recall Preset / User 1 on Section 2 (the right-hand unit)

-Pin 6: recall Preset / User 2 on Section 2 (the right-hand unit)

-Pin 7: recall Preset / User 3 on Section 2 (the right-hand unit)

-Pin 8: recall Preset / User 4 on Section 2 (the right-hand unit)

-Pin 9: common

Momentarily connect pin 9 to the appropriate other pin (1-8) to perform a recall.

To disable remote communications and relay operation

1Press and hold the SETUP button to enter the SETUP menu.

2Use the UP and DOWN buttons to select OFF for each section of the unit.

3Press SETUP to confirm (unit will display password menu).

4Press SETUP to exit.