Setup Menu: DN9340E
7.5. Digital Output Clock Select (Page 4)
This page selects the clock reference for the digital AES/EBU outputs. Note that the output clock reference settings are independent of sampling frequency. The available options are:
•‘System’ – the digital output is locked to the DN9340E’s system clock. Note that this is the default setting.
• ‘DigSRC WCLK’ – the digital output is locked to the word clock reference input located on the rear panel of the unit.
•‘DigIn AB’ – the digital output is locked to the digital input channel’s incoming AES/EBU bit stream. Note that this option may only be selected when the input select is set to ‘DLck AB’, see Section 7.4.
To select the output clock source
1Step through the Set Up menu to the Output Clock select page.
2Use the right control knob to select the clock source.
Note |
| To select ‘DigIn AB’, the unit’s input select must be set to be digital and |
|
| running in ‘DLck AB’ mode, see Section 7.4. |
|
|
|
7.6. Presets lock (Page 5)
This allows the presets to be password protected to prevent unauthorised editing. The password is six characters long.
To set a Presets lock
1Step through the Set Up menu to the Presets lock menu page.
2Use the left and centre control knobs to set a password of six characters, including blank spaces, made up of letters, numbers and/or symbols.
Important! Preliminary and subsequent blank spaces are recorded as part of the
3Turn the right control knob clockwise to cycle to the Lock page.
4Press HOME (SETUP) to apply the Presets lock.
The lock state is retained after power down.
31