Daily maintenance procedures

Daily maintenance procedures

Cleaning the imaging guides

Maintenance procedures that should be performed daily include cleaning the imaging guides, feed and separator rollers and the paper path.

To clean the imaging guides, follow the steps below:

IMPORTANT: Do not use any abrasive materials when cleaning the imaging guides. This includes abrasive cleansers, commercial solvents, paper towels, or coarse cloths.

1.Open the side access door.

2.Release and open the vertical transport plate by rotating the release handle 180° clockwise.

3.Release and remove the front imaging guide by rotating the thumbscrew 90° counterclockwise, and lifting the guide’s two green saddle mounts from the mounting shaft.

Magnets

Front imaging guide

Thumbscrew

Cleaning the imaging guidesRear imaging guide

5-2

A-61140 January 1999