Table 1 — Bar Code Grades

Table 1 illustrates how the dimensional field values are converted to a pass/fail status and the print clarity field values are converted to letter grades:

Table 1 — Bar Code Grades

 

 

 

Grade

 

 

 

 

 

 

 

 

Field

A (Pass)

B

C

D

F (Fail)

 

 

 

 

 

 

W/N

3:1 to 2:1*

 

 

 

2:1 to 1:1*

 

3:1 to 2.2:1**

 

 

 

2.2:1 to1:1**

 

 

 

 

 

 

NEW

0.080 to 0.010

 

 

 

0.009 to 0.000

 

 

 

 

 

 

Contrast

100 to 70

60 to 55

54 to 40

39 to 20

19 to 0

 

 

 

 

 

 

MOD

100 to 70

69 to 60

59 to 50

49 to 40

39 to 0

 

 

 

 

 

 

DEF

0 to 15

16 to 20

21 to 25

26 to 30

31 to 100

 

 

 

 

 

 

RMIN

0 to 49

 

 

 

50 to 100

 

 

 

 

 

 

*Narrow Element Width greater than or equal to 0.020

**Narrow Element Width less than 0.020