Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-66

F-66

TROUBLESHOOTING & REPAIR

CAPACITOR REMOVAL AND REPLACEMENT PROCEDURE (continued)

FIGURE F.30 – OUTPUT CHOKE LEAD DISCONNECTION

LOWER

OUTPUT CHOKE/

IGBT MODULE

TRAY

SPLICED CONNECTION

AREA

 

Return to Section TOC

Return to Master TOC

PROCEDURE

1.Turn off Invertec STT and disconnect main AC input power to the machine.

2.Using the 5/16" nut driver, remove the case wraparound cover.

3.Perform the Input Filter Capacitor Discharge Procedure. See the Maintenance section.

WARNING

ELECTRIC SHOCK can kill.

• Before continuing with the test procedure, perform the capacitor discharge proce- dure to avoid electric shock.

4.Locate the lead connection splice from the output choke to the IGBT module. Remove the insulating sleeve. Using the 7/16" wrench disconnect the lead splice. Thread the lower lead down into the lower tray assembly area. See Figure F.30.

Return to Section TOC

Return to Master TOC

INVERTEC STT

Page 104
Image 104
Lincoln Electric SVM129-B Capacitor Removal and Replacement Procedure, Figure F.30 Output Choke Lead Disconnection