Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR
CAPACITOR REMOVAL AND REPLACEMENT PROCEDURE (continued)
FIGURE F.30 – OUTPUT CHOKE LEAD DISCONNECTION
LOWER | OUTPUT CHOKE/ | |
IGBT MODULE | ||
TRAY | ||
SPLICED CONNECTION | ||
AREA | ||
|
Return to Section TOC
Return to Master TOC
PROCEDURE
1.Turn off Invertec STT and disconnect main AC input power to the machine.
2.Using the 5/16" nut driver, remove the case wraparound cover.
3.Perform the Input Filter Capacitor Discharge Procedure. See the Maintenance section.
WARNING
ELECTRIC SHOCK can kill.
• Before continuing with the test procedure, perform the capacitor discharge proce- dure to avoid electric shock.
4.Locate the lead connection splice from the output choke to the IGBT module. Remove the insulating sleeve. Using the 7/16" wrench disconnect the lead splice. Thread the lower lead down into the lower tray assembly area. See Figure F.30.
Return to Section TOC
Return to Master TOC