G-14

ELECTRICAL DIAGRAMS

G-14

Schematic - Darlington Drive Board - Codes 10151 - 10383 - (M17581)

 

 

Master TOC

18571 M

.5 5W

+V

+V

AUXILLARY

TRANSFORMER WINDING

10VAC

R

D4

8A

J13 400V

2

J13

3

D3

8A

400V

6 J13

R1

D1

8A 400V

C12

3300

50V

D2

8A

400V

C15

3300

50V

 

POWER

C16

SUPPLY

 

 

 

DZ1

18V

1W

10.0

R6

C17

500p

1000V

 

1

3

Q1

 

 

 

 

 

6A

 

 

 

100V

 

 

2

 

W10

R9

R11

10W

2.7

 

 

2.7

Return to Master TOC

6VAC

R

5 J13

GND

 

 

 

0W1 R10

 

 

 

2.7

 

NEGATIVE BIAS

 

 

 

for

 

 

 

DARLINGTON

 

 

 

HOLD - OFF

 

 

 

 

D6

 

 

1N5402

 

D10

D12

 

C10

1N5402

1N5402

D7

 

1N5402

.33

 

 

 

200V

 

 

D8

 

 

 

W01

R12

 

 

2.7

 

 

 

 

 

2.710W

R13

2.7 10W

R14

1.00K

R15

1.00K

2AMP

BASE DRIVE

 

 

.00K

 

 

R16

R17

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

J12

1

1.00K R18

2

DARLINGTON C

MODULE

BLUE B

TWISTED

PAIR

E

BLACK

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

STT CONTROL BOARD

+15V

1K

1

J13

 

ON = Darlington ON

 

 

 

 

OFF = Darlington OFF

 

4

J13

 

 

 

 

R2

1.50K

D5

R3

1.50K

OCI1

2

3

7

HP2201

+V

4R

K92

 

 

 

 

 

 

 

 

.3

267

 

1

VS

 

VS

8

 

 

R5

 

2

IN

X2

OUT

7

 

 

C5

 

 

 

 

 

 

 

3

NC

OUT 6

 

 

DZ2

 

 

 

0.1

4

GND

GND 5

 

 

12V

50V

 

 

1W

 

 

 

4429

 

 

GND

Lae tyou

teGa vDri

Sym tme cri

C6

0.1

50V

D11

D13

1N5402

 

 

 

1N5402

1N5402

D9

 

 

 

 

 

 

1N5402

 

 

 

R8

 

 

20

5W

 

10.0

 

 

G

R7

 

 

 

 

 

 

 

DZ3

C8

 

 

500p

 

 

18V

 

 

1000V

 

 

1W

 

 

 

 

 

 

GND

C9

3300

50V

DQ2

4A

100V

S

J12

J12 3

J12 4

+V

NOTES :

GENERAL INFORMATION

ELECTRICAL SYMBOLS PER E1537

 

CAPACITORS =

MFD

( .022/50V

UNLESS OTHERWISE SPECIFIED)

RESISTORS = Ohms (

 

1/4W

UNLESS OTHERWISE SPECIFIED)

DIODES =

1A, 400V

(UNLESS OTHERWISE SPECIFIED)

 

LAST NO. USED

 

R-

18

DZ- 3

 

C-

17

 

LABELS

D-

13

 

SUPPLY VOLTAGE NET

POWER SUPPLY SOURCE POINT

 

Vcc

8

 

 

C14

OCI1

0.1

 

 

50V

HP2201

 

 

J13

 

 

J12

1

 

3

1

2

 

N.A. SINCE COMPONENTS OR CIRCUITRY ON A PRINTED CIRCUIT BOARD MAY CHANGE

WITHOUT AFFECTING THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY OF CONTROLS HAVING A COMMON CODE NUMBER.

FILE: M17581_1AB

COMMON CONNECTION FRAME CONNECTION

EARTH GROUND CONNECTION

Return to Section TOC

Return to Master TOC

GND 5

GND

4

6

3

4

UNLESS OTHERWISE SPECIFIED TOLERANCE

Ch'ge.Sht.No.

THE LINCOLN ELECTRIC CO.

 

EQUIP.

 

INVERTER WELDERS

ON 2 PLACE DECIMALS IS + .O2

5-19-95

 

TYPE

 

ON HOLES SIZES PER E-2056

 

CLEVELAND, OHIO U.S.A.

 

 

SCHEMATIC, DARLINGTON DRIVE

ON ALL ANGLES IS + .5 OF A DEGREE

3-29-96L

 

SUBJECT

ON 3 PLACE DECIMALS IS + .OO2

 

 

 

 

 

 

 

 

 

MATERIAL TOLERANCE ("t") TO AGREE

 

 

SCALE

NONE

 

BS

 

SHT.

M17581

WITH PUBLISHED STANDARDS

DR.

MLD

DATE

03/23/94

CHK.

SUP'S'D'G.

NO.

 

 

 

 

 

 

 

 

 

NOTE:

Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided

INVERTEC STT & STT II

 

for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result in danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.

Page 130
Image 130
Lincoln Electric SVM129-B service manual Schematic Darlington Drive Board Codes 10151 10383 M17581