TROUBLESHOOTING & REPAIR
T4 AUXILIARY TRANSFORMER TEST (continued)
FIGURE F.4 – PLUG J1 LOCATION
J1 CURRENT
SENSING PLUG
LOWER | OUTPUT CHOKE/ | |
DARLINGTON MODULE | ||
TRAY | ||
SPLICED CONNECTION | ||
AREA | ||
|
5.Disconnect the current sensing Plug J1 from the control PC board. Carefully remove Plug J1 and associated leads from control board compartment. See Figure F.4.
FIGURE F.5 – PLUG J22 LOCATION
PLUG J22
6.Locate and disconnect plug J22 from the wiring harness. See Figure F.5.