T1 AUXILIARY TRANSFORMER TEST (continued)

15. Apply the correct input power and carefully

WARNINGtest for the correct primary voltages at plug J21. See Table F.1.

Return

Return to Section TOC

Return to Section TOC

Return

Return to Master TOC

Return to Master TOC

ELECTRIC SHOCK can kill.

With input power ON, there are high voltages inside the machine. Do not reach into the machine or touch any internal part.

16.If the correct AC input voltages are applied to the primary windings and any or all of the secondary voltages are missing or not cor- rect, the T1 auxiliary transformer may be faulty.