TROUBLESHOOTING & REPAIR
T4 AUXILIARY TRANSFORMER TEST (continued)
FIGURE F.3 – OUTPUT CHOKE/IGBT MODULE SPLICED CONNECTION
LOWER | OUTPUT CHOKE/ | |
DARLINGTON MODULE | ||
TRAY | ||
SPLICED CONNECTION | ||
AREA | ||
|
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
TEST PROCEDURE
1.Turn off the Invertec STT and disconnect main AC input power to the machine.
2.Using the 5/16" nut driver, remove the case wraparound cover.
3.Perform the Input Filter Capacitor Discharge Procedure. See the Maintenance section.
WARNING
ELECTRIC SHOCK can kill.
• Before continuing with the test procedure, per- form the capacitor dis- charge procedure to avoid electric shock.
4.Locate the lead connection splice from the output choke to the IGBT module. Remove the insulating sleeve. Cut any necessary cable ties. Using the 7/16" wrench, discon- nect the lead splice. Thread the lower lead down into the lower tray assembly area. See Figure F.3.