C-3

C-3

ACCESSORIES

Return to Master TOC

Return to Master TOC

LN-742 or STT-10 WIRE FEEDER CONNECTION INSTRUCTIONS

The LN-742 or STT-10 is the recommended wire feed- er for use with the Invertec STT II. Refer to the LN- 742 or STT-10 Operator Manual for Wire Feed Operation. Refer to Figure C.2 or C.3 and follow the instructions below to connect the LN-742 or STT-10.

WARNING

ELECTRIC SHOCK can kill.

Only qualified personnel should perform this installation.

Turn the input power OFF at the discon- nect switch or fuse box before connecting the wire feeder

1.Turn the Invertec STT II power off.

2.Connect the ARC SENSE LEAD MS connector to the mating connector on STT II front panel.

3.Connect the electrode lead (Twist-Mate) to (+) out- put terminal on STT II.

4.Connect the other end of electrode lead (Step #3) and the ARC SENSE LEAD (lead with ring lug, step #2) together to the gun block on the LN 742.

5.Connect work lead between STT (-) terminal and the work piece.

6.Connect the ARC SENSE LEAD “WORK” (lead with alligator clip) to work piece.

NOTE: For best welding performance make this connection as close as possible to the welding arc.

7.Connect the wire feeder control cable between the LN-742 or STT-10 and the 14-pin Wire Feeder Receptacle on the STT II. For the STT-10 Wire Feeder: Connect the second wire feeder control cable between the STT-10 and the 10-pin Remote Receptacle on the STT II.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

WARNING

Turn off input power to the Welding

 

Power source using the disconnnect

 

switch at the fuse box before

 

connecting the wire feeder.

ELECTRIC

Only qualified persons should install,

SHOCK

use or service this machine.

CAN KILL

 

 

CONTROL, ELECTRODE, ARC SENSE "ELECT"

WIRE FEEDER

 

LN 742

REMOTE RECEPTACLE

AND ARC SENSE "WORK" CABLES SHOULD

LN7 GMA

 

BE TAPED TOGETHER.

 

LN9 GMA

 

 

NA5R

 

 

NA5

 

WIRE FEEDER

 

WORK LEAD

CONTROL CABLE

 

 

ELECTRODE LEAD

 

ARC SENSE LEAD ’ELECT"

WORK

CONNECT ELECTRODE LEAD AND "ELECT" ARC SENSE LEAD TOGETHER TO ELECTRODE TERMINAL OF WIRE FEEDER.

ARC SENSE LEAD "WORK" (SHOULD BE LOCATED AS CLOSE AS POSSIBLE TO THE WELDING ARC.)

CRM after 6-10-96

M17657

FIGURE C.2 LN-742 to STT II CONNECTION

INVERTEC STT

Page 23
Image 23
Lincoln Electric SVM129-B LN-742 or STT-10 Wire Feeder Connection Instructions, Figure C.2 LN-742 to STT II Connection