Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-24

F-24

 

 

TROUBLESHOOTING & REPAIR

T4 AUXILIARY TRANSFORMER TEST (continued)

TABLE F.2 – T4 AUXILIARY TRANSFORMER VOLTAGES

TEST POINTS

 

NORMAL VOLTAGES

 

 

 

PLUG J13 PINS 5 TO

6

6VAC

PLUG J13 PINS 2 TO

3

10VAC

PLUG J22 PINS 1 TO

2

18VAC

(LEADS 240 TO 241)

 

 

PLUG J22 PINS 2 TO

9

18VAC

(LEADS 241 TO 242)

 

 

PLUG J22 PINS 3 TO

4

18VAC

(LEADS 243 TO 244)

 

 

PLUG J22 PINS 12 TO

13

18VAC

(LEADS 245 TO 246)

 

 

 

 

 

Return to Section TOC

Return to Master TOC

13.Check the secondary AC voltages accord- ing to Table F.2.

14.With the correct 115VAC applied to the pri- mary winding (#32 to #33), if any or all of the secondary voltages are missing or low, the T4 auxiliary transformer may be faulty. Replace the T4 auxiliary transformer.

15.After all tests are completed, reconnect the following:

Leads #32A, #32B, #33A, #33B to the T4 transformer tabs

Plug J13 to the IGBT drive board

Plug J22 to the wiring harness

Reinstall lower tray assembly using 7/16” wrench and 5 bolts

Plug J1 to the control PC board

Reconnect lead splice from the output choke to the IGBT module. Reposition insulating sleeve.

16. Install the case wraparound cover.

Return to Section TOC

Return to Master TOC

INVERTEC STT

Page 62
Image 62
Lincoln Electric SVM129-B service manual Test Points, Normal Voltages