F-36

TROUBLESHOOTING & REPAIR

SWITCH BOARD TEST (continued)

TABLE F.5 – SWITCH BOARD RESISTANCE TEST (continued)

Apply Positive

Apply Negative

 

 

 

 

Test Probe to

Test Probe to

 

 

 

 

Terminal

Terminal

Test Result

Conclusion

Repair Action

Next Procedure Notes

12

401/403

Greater than

OK

None

Continue

 

 

1K ohm

 

 

 

 

 

Less than

Shorted

Replace both

Snubber Test

 

 

100 ohms

 

switch boards

 

 

 

 

 

 

 

401/403

12

Less than

OK

None

Continue

 

 

100 ohms

 

 

 

 

 

Greater than

Open

Replace both

Snubber Test

 

 

1K ohm

 

switch boards

 

 

 

 

 

 

 

9

402/404

Less than

OK

None

Continue

 

 

100 ohms

 

 

 

 

 

Greater than

Open

Replace both

Snubber Test

 

 

1K ohm

 

switch boards

 

 

 

 

 

 

 

402/404

9

Greater than

OK

None

Continue

 

 

1K ohm

 

 

 

 

 

Less than

Shorted

Replace both

Snubber Test

 

 

100 ohms

 

switch boards

 

 

 

 

 

 

 

NOTE: K ohm = ohm reading multiplied by 1000.

NOTE: Always make sure that switch boards are changed in matched pairs. Never mix an old style (different part number) switch board with a new switch board (new part number).

8.Reconnect all wiring harness leads (401/403, 1/8, 9, 12, 4/5, 402/404) to the switch board.

9.Install the case wraparound cover.