TROUBLESHOOTING & REPAIR

Observe Safety Guidelines

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

WELDING PROBLEMS

 

Molten weld puddle appears exces-

1. The Wire Type switch may be in

1. The IGBT module may be faulty.

sively "violent."

the wrong position for the elec-

Check or replace.

 

trode wire being used.

2. The IGBT driver PC board may

 

 

 

2. The Peak Current or Back-

be faulty.

 

ground Setting may be too high.

3. The control PC board may be

 

Adjust for optimum welding per-

 

faulty.

 

formance.

 

 

 

3. The Tailout may not be set cor-

 

 

rectly for the process. (STT II

 

 

Only)

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed.

Call 1-888-935-3877.