A-2

 

 

 

 

 

INSTALLATION

 

 

 

 

A-2

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS –Invertec STT & STT II

(For Codes 11092 and BELOW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT- THREE PHASE ONLY

 

 

 

STANDARD VOLTAGE

 

 

 

 

INPUT CURRENT AT RATED OUTPUT

 

208/230/460/3/60 HZ

 

32/30/16

 

 

 

 

 

200/220/380/415/440/3/50/60 HZ

33/30/18/17/16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT

 

 

 

 

 

 

DUTY CYCLE

 

 

 

 

AMPS

 

 

VOLTS AT RATED AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60% Duty Cycle

 

 

 

225

 

 

 

 

 

 

29

 

 

100% Duty Cycle

 

 

 

200

 

 

 

 

 

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CURRENT RANGE

 

OPEN CIRCUIT VOLTAGE

 

AUXILIARY POWER

 

Peak Current 1 0 - 450 Amps

 

 

 

85 VDC Maximum

 

115 2 VAC @ 4 Amps

 

Background

 

0 - 125 Amps

 

 

 

 

 

 

 

 

42 VAC @ 4 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT VOLTAGE

FUSE(SUPER LAG)

 

INPUT AMPERE

 

 

TYPE 75 C

 

TYPE 75 C

 

AND FREQUENCY

 

OR BREAKER

 

 

RATING ON

 

 

COPPER

 

COPPER

 

 

 

SIZE

 

 

NAMEPLATE

 

SUPPLY WIRE

 

GROUND WIRE

 

 

 

 

 

 

 

 

 

 

 

 

IN CONDUIT

 

IN CONDUIT

 

 

 

 

 

 

 

 

 

 

 

 

AWG (IEC) SIZES

 

AWG (IEC) SIZES

208/60

40

 

 

 

 

32

 

 

 

 

 

 

 

230/60

40

 

 

 

 

30

 

 

 

 

 

 

 

460/60

30

 

 

 

 

16

 

 

 

 

 

 

 

200/50/60

40

 

 

 

 

33

 

 

 

 

 

 

 

220/50/60

40

 

 

 

 

30

 

 

10 (6 mm2)

 

10 (6 mm2)

380/50/60

30

 

 

 

 

18

 

 

 

 

 

 

 

415/50/60

30

 

 

 

 

17

 

 

 

 

 

 

 

440/50/60

30

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEIGHT

 

WIDTH

 

 

 

 

DEPTH

 

 

WEIGHT

 

23.2 in

 

13.2 in.

 

 

 

 

24.4 in.

 

 

100 lbs.

 

589 mm

 

336 mm

 

 

 

620 mm

 

 

46 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1At low input voltages (below 208 VAC) and input voltages of 380 VAC through 415 VAC there may be a 15% reduction in Peak Current.

2115 VAC not present on European Models.

INVERTEC STT

Page 8
Image 8
Lincoln Electric SVM129-B service manual Installation, INPUT- Three Phase only