Lincoln Electric SVM129-B service manual Figure F.13 Switch Board Test Points

Models: SVM129-B

1 145
Download 145 pages 32.98 Kb
Page 77
Image 77

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-39

F-39

TROUBLESHOOTING & REPAIR

SNUBBER RESISTORS TEST (continued)

FIGURE F.13 - SWITCH BOARD TEST POINTS

401/403

9

12

402/40412

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L8441

SWITCH

to Section TOC

to Master TOC

6.Test for 25 ohms resistance from lead termi- nal 401 to terminal 12 on the switch board. See Figure F.13.

a.If 25 ohms is measured, resistor R4 is OK.

b.If 30 ohms or more is measured, resistor R4 is faulty and must be replaced.

c.If 20 ohms or less is measured, resistor R4 is faulty and must be replaced.

7.Repeat the same procedures to test R5, R6, and R7 according to Table F.6.

8.Reconnect leads 401/403 and 402/404 to the switch board.

9.Install the case wraparound cover.

Return

Return to Section TOC

Return

Return to Master TOC

TABLE F.6 – SNUBBER RESISTORS TEST

Check

Test Result

Conclusion

Next Test Step

Repair Action

 

 

 

 

 

Lead 401 to

25 ohms

OK

Continue

 

Terminal 12

>30 ohms

R4 open

 

Replace R4

 

<20 ohms

R4 faulty

 

 

 

 

 

 

 

Lead 402 to

25 ohms

OK

Continue

 

Terminal 9

>30 ohms

R5 open

 

Replace R5

 

<20 ohms

R5 faulty

 

 

 

 

 

 

 

Lead 403 to

25 ohms

OK

Continue

 

Terminal 12

>30 ohms

R6 open

 

Replace R6

 

<20 ohms

R6 faulty

 

 

 

 

 

 

 

Lead 404 to

25 ohms

OK

Continue

 

Terminal 9

>30 ohms

R7 open

 

Replace R7

 

<20 ohms

R7 faulty

 

 

 

 

 

 

 

> = GREATER THAN < = LESS THAN

INVERTEC STT

Page 77
Image 77
Lincoln Electric SVM129-B service manual Figure F.13 Switch Board Test Points