TROUBLESHOOTING & REPAIR

SNUBBER RESISTORS TEST (continued)

FIGURE F.12 - REMOVING LEADS

Return to Section TOC

Return to Master TOC

TEST PROCEDURE

1.Turn off Invertec STT and disconnect main AC input power to the machine.

2.Using the 5/16" nut driver, remove the case wraparound cover.

3.Perform the Input Filter Capacitor

Discharge Procedure. See the Maintenance section.

WARNING

4.Locate and gain access to the switch board.

5.Remove leads from terminals 401/403, 402/404 on the switch board. See Figure F.12.

Return to Section TOC

Return to Master TOC

ELECTRIC SHOCK can kill.

Before continuing with the test procedure, perform the capacitor discharge procedure to avoid electric shock.