GENERAL (continued) |
|
|
| |
Electrical | Handset |
| 1.0 watt | |
Specifications: | Battery Charger (BC) | 15 watts | ||
(Power) | Radio Module (RM) | 4.0 watts | ||
| Carrier (CA) w/6 RMs | 24.0 watts | ||
| Power Supply (BC) | 15 watts (10V 1.5 A) | ||
| Power Supply (RM) | 6.0 watts (10V 600mA) | ||
| Power Supply (CA) | 30.0 watts (9V) | ||
Battery Pack Life: | Nickel Metal Hydride | 3 hours talk time/22 hours standby time | ||
|
|
|
|
|
RF SYSTEM |
|
|
|
|
PARAMETERS |
|
|
|
|
Frequency Band: | 902 − 928 MHz |
| ||
|
|
|
| |
Channel Spacing: | 150 KHz |
|
| |
|
|
|
|
|
Total Channel | 50 (Channels Dynamically allocated out of 173) | |||
Capability: | ||||
|
| |||
Duplex Method: | Time Division Duplex (TDD) (Transmit and Receive on same frequency) | |||
|
| |||
Transmitter | Dynamic Power Adjustment: 1mW ERP Minimum to 160mW ERP | |||
Output Power: | Maximum |
|
| |
|
|
|
|
|
Receiver |
| |||
Sensitivity: |
| |||
|
|
|
|
|
OTHER |
|
|
|
|
|
|
| ||
Electrical | ■ | 105 −130VAC, 50 −60 Hz, | ||
Requirements: |
| fused at 15 amps. |
| |
| ■ | Outlet must not be controlled by an on/off switch | ||
| ■ | Grounding to comply with Underwriters Laboratories (UL) 1459 | ||
|
| |||
Requirements | Installation of a telephone or other standard (tip/ring) device in another | |||
For | building requires the following | |||
Extensions: | protectors to protect the switch/control unit and telephone device from | |||
| electrical surges: |
| ||
| ■ | MDW 9030P Pocketphone: two Lucent Technologies 503A1 protec- | ||
|
| tors | (ETR); two Lucent Technologies 343B protectors (ATL) | |
|
|
| ||
Wiring: | ■ | MDW 9030P Pocketphone: Lucent Technologies SYSTIMAX® or at | ||
least |
|
| ||
| ■ | Lucent Technologies SYSTIMAX or at least | ||
|
|
| run” not “loop”) ATL |
|
| ■ | Bridging Adapter: Lucent Technologies 267F2 (ETR) | ||
| ■ | Bridging Adapter: Lucent Technologies 267C (ATL) | ||
| ■ | Range: 1,000 feet (305 meters) for the Radio Module (26 AWG) | ||
|
|
|
|
|