III. ASSEMBLY
A.Stacking
If the installation will include upper ovens mounted atop lower ovens:
1. | Remove the casters |
| the upper ovens. |
2. | Stack the oven cavities. If necessary, refer to the Installation |
| Manual for Model PS310/360 Ovens (Middleby P/N 88210- |
SECTION 2 - INSTALLATION
Figure 2-3 - Exploded View, Oven Stand
Attachment
plates inc. w/
upper oven
0025). |
B.Stands
If the installation includes ovens that are to be mounted on stands:
installation kit
ENGLISH
•Remove the casters
•Assemble the ovens to the stands. An exploded view of the stand is shown in Figure
C.Flue Vent(s)
For gas ovens, attach one flue vent to the rear wall of each oven cavity. Use one
IV. THERMOCOUPLE INSTALLATION
1.Install one thermocouple sensing bulb into each of the two holes in the rear panel of the oven, as shown in Figure
2.Thread BOTH sets of thermocouple leads through the grommet and into the machinery compartment, as shown in Figure
3.Remove the
4.Thread the thermocouple leads through the side of the machinery compartment as shown in Figure
5.Connect BOTH sets of thermocouple leads to the tempera- ture controller as shown in Figure
6.Replace the
7.Repeat Steps
Casters inc.
w/oven
Figure 2-4 - Thermocouple Installation Locations
Thermocouples
Figure 2-5 - Placing the Thermocouple Leads
Figure 2-6 - Thermocouple Lead Connections
8=White=Positive
7=Red=Negative R=No Connection
Ground=Shielded cable