Chapter 3: AT Commands Reference
June 30, 2008 AT Commands Reference Manual 3-295
Example
ats100?
001
OK
ats100=0
OK
ats100?
000
OK
+MSCTS, Enable/Disable CTS During Wakeup Period

This command defines the behavior of the CTS line when the G24 is in normal mode (not Sleep

mode).

The command configures the G24 CTS line behavior always to follow the flow control

requirements, or to follow it only if the terminal initiated a serial transmission session. This saves

the terminal from following the CTS interrupt every time the G24 exits Sleep mode for internal

G24 reasons (non-terminal communication related reasons).

Table 3-193:Command parameters

<Parameter> Description Remarks
<delta> Time interval between one burst of sent/received
data to the other before the terminal enters sleep
mode.
0 : Wakeup out feature isn't active. (default when
+S100 set command is never used)
1 - 255: Time in seconds.
This value is saved on power
down.
Command
Type Syntax Response/Action Remarks
Set AT+MSCTS=<control> OK The Set command tells the G24
whether to activate the CTS when the
unit is awakening.
Read AT+MSCTS? +MSCTS: <current
control>
OK
The Read command returns the current
control value.
Test AT+MSCTS=? +MSCTS: (list of
supported <control>)
OK
The Test command returns the possible
control values.