Hardware Information
3-232 AT Commands Reference Manual June 30, 2008
+MVREF, Motorola Voltage Reference

This command defines the Vref regulator's configuration. Pin 27 is used as indicator signal that

reflects the configuration of Vref regulator. This command is a basic command. The command is

also sensitive to ATS24 command.

The following table shows the +MVREF parameters.

Example
AT+MVREF=?
+MVREF:(0-2)
OK
AT+MVREF=1
OK
AT+MVREF?
+MVREF: 1
Command
Type Syntax Response/Action Remarks
Set +MVREF=<control> OK
or:
+CME ERROR: <err>
The Set command is used for setting
the behavior of Vref regulator.
Read +MVREF? +MVREF: <control>
OK
or:
+CME ERROR: <err>
The Read command returns the current
behavior <control> value.
Test +MVREF=? +MVREF: (0-2)
OK
The Test command returns the possible
values' range.

Table 3-148: +MVREF Parameters

<Parameter> Description
<control> 0 OFF mode.
1 ON mode.
2 STANDBY mode (default).
For additional information about pin 27’s signals, see Table3-149.

Table 3-149:+MVREF Signals Values

Mode Volta ge Current
00V 0A
1 2.75V 50mA
2 2.75V ATS24 is 0: 50mA
ATS24 is not 0: The current is
changed alternately from 50mA to
2mA and back to 50mA.