Call Control
3-40 AT Commands Reference Manual June 30, 20 08
+MFIC, Filtering Incoming Calls

This command instructs the G24 to query or set Filtering Incoming Calls parameters. The

command is a "none basic" command and will not work if SIM card is not present or if SIM card

is not in READY state.

MFIC parameters are saved after power cycle.

This feature is not active by default, however, changing the FLEX can activate it.

Command
Type Syntax Response/Action Remarks
Set +MFIC=[<state>[,<pb>[
,<response>[,<pb_range
>]]]]
OK
or:
+CME ERROR: <err>
The set command defines the
Incoming Calls Filtering parameters -
this command enable/disable the
filtering, set the search phone book,
define the respond type and set the
search phone book entries range.
Each of the parameters has its own
default value, which will take effect if
it is omitted from the command line. In
case the parameter is omitted with its
pre - leading comma, then the already
set value will not be changed to its
default. See examples bellow.
One exceptional is the dealing with the
<pb_range> parameter. When
changing the search <pb> without also
changing/setting the <pb_range>, there
is a possibility that the already set
<pb_range> is too big for the new
search <pb>. For example, when
changing from "MT" to "SM"/"ME"
while the <pb_range> is equal to 235.
The "SM"/"ME" phone books may not
hold so many entries. In such cases the
new search <pb> maximum size will
be set as the new value of the
<pb_range>.
Read + MFIC? +MFIC=<state>,<pb>,<
response>,<pb_range>
OK
The read command returns the current
MFIC set parameters value.
Test + MFIC=? +MFIC: (list of
supported <state>s),(list
of supported <pb>s),(list
of supported
<response>s),(list of
supported <pb_range>)
OK
or:
+CME ERROR: <err>
The test command returns the possible
ranges of MFIC parameters.