Operating Procedures
Working with Relocatable Sections
MCUez HC12 Assembler User’s Manual
MOTOROLA Operating Procedures 223
The minimal linker parameter file will look like this:
LINK test.abs /* Name of the executable file generated. */
NAMES
test.o /* Name of the object files in the application. */
END
SEGMENTS
/* READ_ONLY memory area. */
MY_ROM = READ_ONLY 0x0B00 TO 0x0BFF;
/* READ_WRITE memory area. */
MY_RAM = READ_WRITE 0x0800 TO 0x08FF;
END
PLACEMENT
/* Relocatable variable sections are allocated in MY_RAM. */
DEFAULT_RAM INTO MY_RAM;
/* Relocatable code and constant sections are allocated in MY_ROM. */
DEFAULT_ROM INTO MY_ROM;
END
INIT entry /* Application entry point. */
VECTOR ADDRESS 0xFFFE entry /* Initialization of the reset vector. */
NOTE:
The programmer should ensure that the memory ranges specified in the
SEGMENT block are valid addresses for the MCU being used.
The module fibo.asm located in the demo directory is a small example of using