User’s Manual MCUez HC12 Assembler
288 Assembler Messages MOTOROLA
Assembler Messages
12.3.48 A12005: Value Must Be Between 1 and 8
Type: Error
Description: The expression specified in a pre-increment, post-increment,
pre-decrement, or post-decrement addressing mode is out of
the range [1...8].
Example:
STX 10, SP+
Tip: According to the HC12 addressing mode notation, the
increment or decrement factor must be bigger than 0 and
smaller than 9.
12.3.49 A12007: Comma Expected
Type: Error
Description: A comma character (,) is missing between two instructions or
directive operands.
Example:
DataSec: SECTION SHORT
Data: DS.B 1
CodeSec: SECTION
MOVB #$55 data
Tip: Use the comma character as a separator between instruction
operands.
Example:
DataSec: SECTION SHORT
Data: DS.B 1
CodeSec: SECTION
MOVB #$55, data