Assembler Messages
Message Codes
MCUez HC12 Assembler User’s Manual
MOTOROLA Assembler Messages 275
12.3.34 A2327: ON or OFF Expected
Type: Error
Description: The syntax for an MLIST or CLIST directive is not correct.
These directivesexpect a unique operand, which take the value
ON or OFF.
Example: CodeSec: SECTION
CLIST
Tip: Specify either ON or OFF after the MLIST or CLIST directive.
Example:
CodeSec: SECTION
CLIST ON
12.3.35 A2328: Value is Truncated
Type: Warning
Description: The size of one of the constants listed in a DC directive is
bigger than the size specified in the DC directive.
Example: DataSec: SECTION
cst1: DC.B $56, $784, $FF
cst2: DC.w $56, $784, $FF5634
Tip: Reduce the value of the constant to the size specified in the DC
directive.
Example: DataSec: SECTION
cst1: DC.B $56, $7, $84, $FF
cst2: DC.W $56, $784, $FF, $5634