Device User Guide — 9S12C128DGV1/D V01.05

This is very important to notice with respect to timers, serial modules where a pre-scaler will eliminate the effect of the jitter to a large extent.

Table B-12 PLL Characteristics

Conditions are shown in Table A-4 unless otherwise noted

Num

C

Rating

Symbol

Min

Typ

Max

Unit

 

 

 

 

 

 

 

 

1

P

Self Clock Mode frequency

fSCM

1

 

5.5

MHz

2

D

VCO locking range

fVCO

8

 

50

MHz

3

D

Lock Detector transition from Acquisition to Tracking

Δtrk

3

 

4

%1

 

 

mode

 

 

 

 

 

4

D

Lock Detection

ΔLock

0

 

1.5

%(1)

5

D

Un-Lock Detection

Δunl

0.5

 

2.5

%(1)

6

D

Lock Detector transition from Tracking to Acquisition

Δunt

6

 

8

%(1)

 

 

mode

 

 

 

 

 

7

C

PLLON Total Stabilization delay (Auto Mode) 2

tstab

 

0.5

 

ms

8

D

PLLON Acquisition mode stabilization delay (2)

tacq

 

0.3

 

ms

9

D

PLLON Tracking mode stabilization delay (2)

tal

 

0.2

 

ms

10

D

Fitting parameter VCO loop gain

K1

 

-100

 

MHz/V

11

D

Fitting parameter VCO loop frequency

f1

 

60

 

MHz

 

 

 

 

 

 

 

 

12

D

Charge pump current acquisition mode

ich

 

38.5

 

μA

 

 

 

 

 

 

 

 

13

D

Charge pump current tracking mode

ich

 

3.5

 

μA

 

 

 

 

 

 

 

 

14

C

Jitter fit parameter 1(2)

j1

 

 

1.1

%

15

C

Jitter fit parameter 2(2)

j2

 

 

0.13

%

NOTES:

1.% deviation from target frequency

2.fOSC = 4MHz, fBUS = 25MHz equivalent fVCO = 50MHz: REFDV = #$03, SYNR = #$018, Cs = 4.7nF, Cp = 470pF, Rs = 10KΩ.

115

Page 115
Image 115
Motorola MC9S12C-Family, MC9S12GC-Family warranty Table B-12 PLL Characteristics, Num Rating Symbol Min Typ Max Unit