210 Main office configuration
Zone parameters
Zone parameters must be configured at both the main office Call Server
and MG 1000B Call Server. The main office procedure is similar to an IP
Peer Network configuration with the Branch Office-specific configuration
outlined in this chapter.
Zone parameters are defined at the main office in LD 117 (see Procedure
9 "Configuring ESN and MG 1000B zones" (page 210)) and applied to IP
Phones in LD 11 (see Procedure 27 "Installing IP Phones through overlays"
(page 279)).
Time adjustments for zones are configured in LD 117 and defined relativeto
the time set in LD 2.
"EmergencySer vices configuration" (page 315) describes ESA configuration
in the dialing plan for the main office and Branch Office.
Procedure 9
Configuring ESN and MG 1000B zones
Step Action
WARNING
Before and after an upgrade, perform a datadump (using LD 43
EDD or through Element Manager) on the Call Server to back up
the existing data.
1Configure the Home Location Code (HLOC), and the Virtual Private
Network Identifier (VPNI).
LD 15 Configure Customer Data Home Location Code and Virtual Private Network Identifier.
Prompt Response Description
REQ: CHG Change existing data.
TYPE: NET ISDN and ESN Networking options
CUST Customer number
0-99 Range for Large System and CS 1000E system
0-31 Range for Small System and Media Gateway 1000B.
...
CLID YES Allow Calling Line Identification option
- ENTRY xx CLID entry to be configured
- - HLOC 100-9999999 Home Location code (ESN) (3-7 digits)
ISDN YES Integrated Services Digital Network
Nortel Communication Server 1000
Branch Office Installation and Commissioning
NN43001-314 01.02 Standard
Release 5.0 20 June 2007
Copyright© 2007, Nor tel Networks
.