Firmware downloads 347
The umsUpgradeAll command has no immediate impact on IP Phones
that are logged in or out by Virtual Office. However, the firmware files may
be upgraded, if required, when the Virtual Office session is terminated.
For information on Enhanced UNIStim Firmware, refer to IP Line
Fundamentals (NN43100-500).
Each IP Phone that is redirected back to the BranchOffice has its fir mware
version checked againstthe MG 1000B TPS firmware policy. If there is
no match, the firmware is upgraded automatically and the IP Phone is
redirected back to the main office. If there is a match, the IP Phone stays
in Local Mode, and "Required firmware <version> is displayedon the
telephone screen (seeFigure 118 "Required firmware version" (page 347)).
Figure 118
Required firmware version
This figure shows a screen display from an IP Phone 2004. The display on
another model of IP Phone may differ.
This display can only be clearedby pressing the Cancel key. While this
display appears, the user can only receivecalls; they cannot make outgoing
calls.
Procedure 45
Upgrading firmware for CS 1000 Release 5.0
Step Action
Upgrade procedures are generally found in theCommunication Server
1000E: Installation and Configuration NTP (NN43041-310). Relevant
information can be found in IP Line: Description, Installation, and Operation
(NN43100-500).
1At the main office, upgrade IP Phone firmware on the Signaling
Server. For instructions, see the chapter "Uploading software
upgradefiles" in Communication Ser ver 1000E: UpgradeProcedures
(NN43041-458).
2Issue the CLI command umsUpgradeAll at the main office.
Nortel Communication Server 1000
Branch Office Installation and Commissioning
NN43001-314 01.02 Standard
Release 5.0 20June 2007
Copyright© 2007, Nor tel Networks
.