371
Appendix BBranch Office engineering example
Contents This section contains information on the following topics:
"Introduction" (page 371)
"Assumptions" (page 372)
"Calculations" (page 373)
"Traffic" (page 373)
"MG 1000B Core and MG 1000B Expander requirements" (page 375)
"Bandwidth requirements" (page 377)
"Branch Office conference engineering" (page 379)
IntroductionThis chapter provides sample engineer ing calculations fora Branch Office
with a CS 1000M or CS 1000E main office.
The following abbreviationsare used in formulas:
IT = IP Phone
AT= analog (500/2500-type) telephone
MC = Media Card
Nortel Communication Server 1000
Branch Office Installation and Commissioning
NN43001-314 01.02 Standard
Release 5.0 20 June 2007
Copyright© 2007, Nor tel Networks
.