Signaling Server software installation 243
Signaling Server port speed
Use Procedure 19 "Changing the Signaling Server port speed" (page 243)
to change the initial port speed of the Signaling Server for a maintenance
terminal connection. This procedure is optional.
Procedure 19
Changing the Signaling Server port speed
Step Action
1Make sure the DTE–DTE null modem cable (supplied with the
Signaling Server) runs from the back port of the Signaling Server to
the maintenance terminal.
2Press <CR> to see the login prompt. The Signaling Ser vermust
boot successfully before the user can log in.
3Log in to the Signaling Server.
ATTENTION
If the Signaling Server has connected to the Call Server (the startup
messages indicate whether or not the linkis up), use the PWD1 login to
access the Signaling Server.
The default Signaling Server Command Line Interface (CLI) login
and password is:
Login = admin
Password = cseadmin
The system immediately prompts a change to the default password.
ATTENTION
If you forgetthe password, reset it from the Tools Menu (see Procedure
18 "Viewing the ToolsMenu" (page 241)).
4Enter stty 9600 to change the port speed to 9600 baud.
Acceptable values for the maintenance port speed are 9600, 19
200, 38 400, and 115 200.
5Change the port speed on the terminal, terminal emulator, or
workstation (which can require a terminal emulator reset).
6Press <CR> several times to make sure the command line prompt is
visible at the new speed.
7Enter exit to log out of the CLI.
Nortel Communication Server 1000
Branch Office Installation and Commissioning
NN43001-314 01.02 Standard
Release 5.0 20June 2007
Copyright© 2007, Nor tel Networks
.