Preparation Chapter 5  

Checking CAC data number and CAC data during operation

1 Open the LENS SETUP screen.

For details on menu operation, refer to [Using the menus] (page 129).

2 Turn the JOG dial button to select CAC PROPERTY and select DISPLAY to open the CAC PROPERTY screen.

The CAC property list appears.

LENS SETUP

SHADING SELECT

DEFAULT

 

SHADING(USER)

>>>

 

CAC

ON

 

CAC PROPERTY

 

RETURN

 

CAC CARD READ

 

DISPLAY

 

CAC FILE DELETE

 

 

>>>

 

CAC FILE INIT

>>>

 

IRIS ADJUST

>>>

 

PUSH MENU TO RETURN

CAC Property

 

 

 

 

 

 

a

 

 

CAC PROPERTY

 

 

 

 

 

 

 

 

ACTIVE CAC FILE NO : 1

 

 

 

b

 

 

 

FILE NO

: 1

 

 

 

 

 

 

 

 

MAKER

: FUJINON

 

 

 

TYPE

:

 

 

 

 

c

 

XT17X4.5BRM-K14

 

 

VERSION : 1.00-00-0.00

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA ERROR

 

 

d

 

PLEASE READ CAC CARD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PUSH MENU TO RETURN

 

 

 

aCurrent CAC data number

bData number of CAC you wish to check Turn the JOG dial to select.

cCAC data of the specified file (b)

dError messages

The file cannot be used if an error message appears. Initialize the CAC data or reload the CAC file from an SD card.

For details, see [Initializing CAC File] (page 103) or [Loading CAC File From an SD Card] (this page).

Loading CAC File From an SD Card

1

Open the LENS SETUP screen.

 

For details on menu operation, refer to [Using the

 

menus] (page 129).

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Use the JOG dial button to select CAC CARD

 

READ. Then select EXECUTE to open the CAC

 

CARD READ screen.

 

 

 

 

 

 

 

LENS SETUP

 

 

SHADING SELECT

DEFAULT

 

 

SHADING(USER)

>>>

 

 

 

 

CAC

ON

 

 

CAC PROPERTY

>>>

 

 

 

 

CAC CARD READ

 

RETURN

 

 

 

CAC FILE DELETE

 

EXECUTE

 

 

 

 

CAC FILE INIT

 

 

 

 

 

>>>

 

 

 

 

IRIS ADJUST

>>>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PUSH MENU TO RETURN

 

 

 

 

 

 

 

 

 

3

Use the JOG dial button to select the CAC file

to load. Then select YES and press the JOG dial button.

CAC CARD READ

ZT17X4.5BRM-K1

PUSH MENU TO RETURN

CAC FILE READ

CAC FILE NO:1

READ?

 

 

 

 

YES

PUSH SET

 

NO

 

102