•P2 MICON ERROR: The P2 microprocessor does not respond
•TEMPORARY PAUSE
IRREGULAR FRM SIG:
This message indicates that the input GENLOCK reference signal is irregular and that recording has been paused.
• TURN POWER OFF
This message indicates that an abnormal event has occurred, for example, that a card was removed during access or that a system mode change was made. Turn the power off and then turn it back on again.
• WIRELESS RF
This message indicates that reception from the wireless receiver is poor.
Camera status display
• ABB
ABB indicator
• ATW ACTIVE
Appears when the AUTO W/B BAL switch is set to AWB and ATW is running.
• ATW (ATW LOCK)
Appears when the WHITE BAL switch is set to B and ATW has been assigned.
• AUTO KNEE (ON/OFF)
Displayed when changing the AUTO KNEE switch position.
• AWB
AWB indicator
• AWB P3.2K/AWB P5.6K
Displays the color temperature assigned to PRST when the WHITE BAL switch is set to PRST. Also displayed when AWB is performed in the PRST position.
• BACK LIGHT (OFF)
Displayed during iris control when back light status is changed by pressing the user button to which BACK LIGHT is assigned.
• DRS ON (OFF)
Displayed when DRS operation has been changed.
• GAIN**dB
Displayed when GAIN is switched.
• ND NG
Displayed when the ND filter is not positioned correctly.
• SCENE******
Displays the name of a scene file selected by turning the SCENE FILE dial.
• SHUTTER 1/**** (OFF)
Displayed when the shutter speed is changed.
• SPOT LIGHT (OFF)
Displayed during iris control when back light status is changed by pressing the user button to which SPOT LIGHT is assigned.
• FBC ON (OFF)
Displayed when FBC operation has been changed.
Adjustments ChapterandSettings 4rding rfoRec