| Camera operating conditions | Camera setup | GENLOCK input and camera output phase | ||||
|
|
|
|
| (In phase: Out of phase: ×) | ||
Recording |
| Video and reference |
|
|
| VIDEO OUT, |
|
| signal to be output | GENLOCK input | GL PHASE | SDI OUT (HD) | TC OUT | ||
format |
| SDI OUT (SD) | |||||
| externally |
|
|
|
| ||
|
|
|
|
|
|
| |
|
| SDI OUT (1080i) | 1080i | SDI | | 90H delay | |
1080i |
| VIDEO OUT | COMPOSITE | 90H advance | | | |
|
| ||||||
| SDI OUT (1080i) | SD (480i (576i)) | SDI | | 90H delay | | |
|
| ||||||
|
| VIDEO OUT | COMPOSITE | 90H advance | | | |
|
|
| |||||
|
| SDI OUT (720P) |
| SDI | | 120H delay | × |
|
| VIDEO OUT | 720P | COMPOSITE | 120H | | × |
|
|
| advance | ||||
720P |
|
|
|
|
|
| |
| SDI OUT (720P) |
| SDI | | 120H delay | | |
|
|
| |||||
|
| VIDEO OUT | SD (480i (576i)) | COMPOSITE | 120H | | |
|
|
| advance | ||||
|
|
|
|
|
|
| |
480i (576i) |
| SDI OUT (480i (576i)) | SD (480i (576i)) | Disabled | No output | | |
| VIDEO OUT | ||||||
|
|
|
|
|
|
|
Pressing the COUNTER button to view the counter displays the counter value on the time code indicator in the LCD and in the viewfinder. The counter value is indicated in “Hour : Minute : Second” format. The counter value is not displayed during playback.
The menu option REC COUNTER in the DISPLAY SETUP screen can be set to display two types of counters.
TOTAL: provides a continuous count until reset by pressing the COUNTER RESET button. The counter value is retained when P2 cards are replaced and when the power is turned off.
CLIP: The counter is reset to 0 at the start of each recording and allows you to keep track of clip recording time while shooting the current clip.
NOTE
•Pressing the RESET button when the counter value is displayed resets the counter to 0.
•The counter value indicates values in the range between 0:00:00 and 9:59:59 in
Adjustments ChapterandSettings 4rding rfoRec