Item

Setting

Notes

 

HYTRON50 NEAR

Sets the near end voltage for HYTRON50. (Adjustable

 

 

 

 

in 0.1 V units.)

 

 

 

 

11.0 V ... 13.4 V ... 15.0 V

 

 

 

HYTRON140 NEAR

Sets the near end voltage for HYTRON140.

 

 

 

 

(Adjustable in 0.1 V units.)

 

 

 

 

11.0 V ... 13.1 V ... 15.0 V

 

 

 

DIONIC90 NEAR

Sets the near end voltage for DIONIC90. (Adjustable

 

 

 

 

in 0.1 V units.)

 

 

 

 

11.0 V ... 13.7 V ... 15.0 V

 

 

 

DIONIC160 NEAR

Sets the near end voltage for DIONIC160. (Adjustable

 

 

 

 

in 0.1 V units.)

 

 

 

 

11.0 V ... 13.3 V ... 15.0 V

 

 

7  

NP-L7 NEAR

Sets the near end voltage for NP-L7. (Adjustable in 0.1

 

 

 

V units.)

 

 

 

 

 

 

 

 

11.0 V ... 13.6 V ... 15.0 V

 

 

 

ENDURA7 NEAR

Sets the near end voltage for ENDURA7. (Adjustable

 

 

MenuOperationsChapter

 

in 0.1 V units.)

 

 

 

 

 

 

 

11.0 V ... 13.4 V ... 15.0 V

 

 

 

ENDURA10 NEAR

Sets the near end voltage for ENDURA10. (Adjustable

 

 

 

 

in 0.1 V units.)

 

 

 

 

11.0 V ... 13.4 V ... 15.0 V

 

 

 

ENDURA-D NEAR

Sets the near end voltage for ENDURA-D. (Adjustable

 

 

 

 

in 0.1 V units.)

 

 

 

 

11.0 V ... 13.4 V ... 15.0 V

 

 

 

PAG L95 NEAR

Sets the near end voltage for PAG L95. (Adjustable in

 

 

 

 

0.1 V units.)

 

 

 

 

11.0 V ... 13.8 V ... 15.0 V

 

 

 

BP-GL65/95 NEAR

Sets the near end voltage for BP-GL65/95. (Adjustable

 

 

 

 

in 0.1 V units.)

 

 

 

 

11.0 V ... 13.4 V ... 15.0 V

 

 

 

NiCd14 NEAR

Sets the near end voltage for NiCd14. (Adjustable in

 

 

 

 

0.1 V units.)

 

 

 

 

11.0 V ... 13.5 V ... 15.0 V

 

 

 

NiCd14 END

Sets the end voltage for NiCd14. (Adjustable in 0.1 V

 

 

 

 

units.)

 

 

 

 

11.0 V ... 13.1 V ... 15.0 V

 

 

 

TYPE A FULL

Sets the full voltage for TYPE A. (Adjustable in 0.1 V

 

 

 

 

units.)

 

 

 

 

12.0 V ... 15.7 V ... 17.0 V

 

 

 

TYPE A NEAR

Sets the near end voltage for TYPE A. (Adjustable in

 

 

 

 

0.1 V units.)

 

 

 

 

11.0 V ... 13.7 V ... 15.0 V

 

 

 

TYPE A END

Sets the end voltage for TYPE A. (Adjustable in 0.1 V

 

 

 

 

units.)

 

 

 

 

11.0 V ... 13.3 V ... 15.0 V

 

 

 

TYPE B FULL

Sets the full voltage for TYPE B. (Adjustable in 0.1 V

 

 

 

 

units.)

 

 

 

 

12.0 V ... 16.0 V ... 17.0 V

 

 

 

TYPE B NEAR

Sets the near end voltage for TYPE B. (Adjustable in

 

 

 

 

0.1 V units.)

 

 

 

 

11.0 V ... 13.1 V ... 15.0 V

 

 

 

TYPE B END

Sets the end voltage for TYPE B. (Adjustable in 0.1 V

 

 

 

 

units.)

 

 

 

 

11.0 V ... 12.8 V ... 15.0 V

 

 

 

NEAR END CANCEL

Sets to cancel battery near end warning. ON, OFF.

 

 

 

 

ON, OFF

 

 

 

 

• When set to ON, pressing the DISP/MODE CHK

 

 

 

 

button stops the flashing of warning and tally lamps.

 

 

 

 

 

____ indicates the factory setting

145