[NETWORK] menu

■■Error information page

When [Error (Detail)] or [Warning (Detail)] is displayed in the self-diagnosis display of the [Projector status] screen, click it to display the error/warning details.

zzThe projector may go into the standby status to protect the projector depending on the contents of the error.

[OK]: Normal operation [FAILED]: Occurrence of trouble [WARNING]: Warning

zzDescription of problem occurrence [FAILED]:

Parameter

Description

[MAIN CPU BUS]

There is a problem with the microcomputer circuitry. Consult your

dealer.

 

[FAN]

There is a problem with the fan or the fan drive circuit. Consult your

dealer.

 

 

The air intake temperature is too high. It may be used in an operating

[INTAKE AIR TEMPERATURE]

environment where the temperature is high, such as near a heating

 

appliance.

 

The temperature inside the projector is high. It may be used in an

[OPTICS MODULE TEMPERATURE]

operating environment where the temperature is high, such as near

 

a heating appliance.

[AROUND LAMP TEMPERATURE]

The temperature around the lamp is high. The air exhaust port may

be blocked.

 

[LAMP1 REMAIN TIME]

 

[LAMP2 REMAIN TIME]

The usage time of the lamp has exceeded the specified time, and it

[LAMP3 REMAIN TIME]

is time to replace the lamp.

[LAMP4 REMAIN TIME]

 

[LAMP1 STATUS]

 

[LAMP2 STATUS]

The lamp has failed to turn on. Wait a while until the luminous lamp

[LAMP3 STATUS]

cools off, and then turn on the power.

[LAMP4 STATUS]

 

[APERTURE(CONTRAST-SHUTTER)]

There is a problem in the contrast shutter circuit for dynamic iris.

Consult your dealer.

 

[SHUTTER(MUTE-SHUTTER)]

There is a problem with the shutter circuitry. Consult your dealer.

[INTAKE AIR TEMP.SENSOR]

There is a problem with the sensor used to detect intake air

temperature. Consult your dealer.

 

[OPTICS MODULE TEMP.SENSOR]

There is a problem with the sensor used to detect temperature inside

the projector. Consult your dealer.

 

Settings

ENGLISH - 129