Connecting

■■For <SDI IN 1>/<SDI IN 2> terminals (for PT-DZ21KU and PT-DS20KU only)

Started Getting

+'6',VLJQDORU

6'6',VLJQDO

'LJLWDO9&5IRUFRPPHUFLDOXVH

Note

zzUse [SYSTEM SELECTOR] ( page 70) to switch the input format.

zzSome external devices to be connected require [SDI IN] ( page 93) to be set.

zzUse a 5CFB or higher (such as 5CFB, or 7CFB) or a Belden 1694A or higher connection cable to properly transmit images. Use a connection cable of 100 m (328'1") length or less.

zzTo enter dual link signals, the [SDI LINK] in [SDI IN] must be set.

zzUse the same length and same type of cables to connect <SDI IN 1>/<SDI IN 2> terminals when entering dual link signals. If there is a difference of 4 m (13'1") or greater in cable length, images may not be projected properly.

zzTo input dual link signals, connect directly without going through a distributor or other such device to the external device which outputs signals. A phase difference may occur between the LINK-A signal and the LINK-B signal and images may not be projected properly.

zzWhen an unsteady signal is connected, an error in signal detection may occur. In such a case, use the [SYSTEM SELECTOR] ( page 70) to switch to a system that matches the signal format.

46 - ENGLISH