Paradyne U8777, 8779 manual Table A-7. System Options 1, DSL Mode, Test Timeout, Ltu

Models: U8777 8779

1 182
Download 182 pages 21.75 Kb
Page 109
Image 109

A. Configuration Options

System Options

For System Options, refer to Table A-7, System Options. To access the System

Options screen, follow this menu selection sequence:

Main Menu Configuration Current Configuration System Options

main/config/system

 

 

Slot: 18

 

Model: 87xx

SYSTEM OPTIONS

 

 

DSL Mode:

LTU

 

Test Timeout:

Enable

 

Test Duration (min):

10

 

Telco Initiated Loopbacks:

Enable

(Model 8777)

Remote Telco Line Loopback:

Disabled

(Model 8777)

G.703 Line Termination

120 Ohm

(Model 8779)

--------------------------------------------------------------------------------

Ctrl-a to access these functions, ESC for previous menu

MainMenu Exit

Save

 

Table A-7. System Options (1 of 2)

DSL Mode

Possible Settings: LTU, NTU

Default Setting: LTU

Controls whether the unit is configured as a control unit or tributary unit.

LTU – The unit is configured as a control unit (Line Termination Unit).

NTU – The unit is configured as a tributary unit (Network Termination Unit). This unit will request its IP address from the LTU during establishment of the PPP link.

NOTE: Changing this option will reset the card.

Test Timeout

Possible Settings: Enable, Disable

Default Setting: Enable

Allows tests to end automatically. The feature should be enabled when the unit is remotely managed, so that control can be regained after a test is accidentally executed.

Enable – Loopback and pattern tests end when test duration is reached.

Disable – Tests run until manually terminated from the Network Tests screen or remotely (network initiated tests). Refer to Running Network Tests in Chapter 8, Testing.

8700-A2-GB20-40

May 2002

A-13

Page 109
Image 109
Paradyne U8777, 8779 manual Table A-7. System Options 1, DSL Mode, Test Timeout, Ltu