Standards Compliance for SNMP Traps

B

SNMP Traps

his section describes the unit’s compliance with SNMP standards and any special operational features for the SNMP traps supported. The unit supports the following traps:

warmStart on page B-2

authenticationFailure on page B-2

TlinkUp and linkDown on page B-2Enterprise-Specific Traps on page B-4

ifIndex

The object ifIndex is a variable binding for several traps. The following ifIndex values are supported for Hotwire 87xx TDM SDSL Termination Units:

ifIndex

Description

 

 

3–10

DSL Interface Ports 1–8

 

 

15–22

DSX-1 or G.703 Interface Ports 1–8

 

 

39–46

EOC Management Link Ports 1–8

 

 

For a unit defined as an LTU running IP Conservative software or a unit not running IP Conservative software, all traps have at a minimum a variable binding of the Overloaded ifIndex (OI). The formula for the OI is:

((LTU Slot Number) * 1,000) + ifIndex.

8700-A2-GB20-40

May 2002

B-1

Page 139