Paradyne U8777, 8779 manual IfType RFC 8700-A2-GB20-40 May

Models: U8777 8779

1 182
Download 182 pages 21.75 Kb
Page 143
Image 143

B. Standards Compliance for SNMP Traps

SNMP Trap

Description

Possible Cause

 

 

 

enterpriseFallback

After a loss of signal, the

Variable line conditions.

AutoRate(13)

unit resynchronized to a

 

 

lower rate than the last

 

 

known rate.

 

 

Variable bindings:

 

 

ifIndex (RFC 2863)

 

 

ifAdminStatus

 

 

(RFC 2863)

 

 

TifOperStatus (RFC 2863)

 

 

ifType (RFC 2863)

 

 

 

 

enterprisePrimaryClockFail

he LTU has recovered and

 

Clear(101)

is using its primary clock

 

 

source.

 

 

No variable bindings.

 

 

 

 

enterpriseSecondaryClock

he LTU has recovered and

 

FailClear(104)

is using its secondary clock

 

 

source.

 

 

No variable bindings.

 

 

 

 

enterpriseTestStop(105)

All tests have been halted.

All tests on an interface have

 

Variable bindings:

been stopped by timeout or

 

an Abort All Tests command.

 

 

 

ifIndex (RFC 2863)

 

 

ifAdminStatus

 

 

(RFC 2863)

 

 

ifOperStatus (RFC 2863)

 

 

TifType (RFC 2863)

 

 

ifTestType (RFC 2863)

 

 

 

 

enterpriseFallback

After an AutoRate fallback

 

AutoRateClear(113)

condition, the unit

 

 

resynchronized to the last

 

 

known rate.

 

 

Variable bindings:

 

 

ifIndex (RFC 2863)

 

 

ifAdminStatus

 

 

(RFC 2863)

 

 

TifOperStatus (RFC 2863)

 

 

ifType (RFC 2863)

 

 

 

 

8700-A2-GB20-40

May 2002

B-5

Page 143
Image 143
Paradyne U8777, 8779 manual IfType RFC 8700-A2-GB20-40 May