B. Standards Compliance for SNMP Traps

For a unit defined as an NTU running IP Conservative software, all traps have at a minimum a variable binding of the Super Overloaded ifIndex (SOI). The formula for the SOI is:

((LTU Slot Number) * 1,000,000)

+((LTU DSL Port Number) * 1,000)

+the NTU’s ifIndex.

warmStart

 

SNMP Trap

Description

Possible Cause

 

 

 

 

 

warmStart

he unit has reinitialized

TReset command.

 

 

itself.

 

Power disruption.

 

 

 

 

 

 

he trap is sent after the unit

 

 

 

resets and stabilizes.

 

 

 

No variable bindings.

 

 

 

 

 

 

authenticationFailure

 

 

 

 

 

 

 

 

SNMP Trap

Description

Possible Cause

 

 

 

 

 

authenticationFailure

Failed attempts to access the

Three unsuccessful attempts

 

 

unit.

 

were made to enter a correct

 

 

VariableT

bindings:

login/password combination.

 

 

devAuthentication

 

 

 

FailureIPAddress

 

 

 

(Health & Status MIB)

 

 

 

Returns zero if the IP

 

 

 

address is unknown or the

 

 

 

failure came from the

 

 

 

terminal port.

 

 

 

 

 

 

linkUp and linkDown

he link SNMP traps are:

linkUp – The unit recognizes that one of the communication interface is

Toperational.

linkDown – The unit recognizes that one of the communication interface is not operational.

The network and synchronous port interfaces (physical sublayer) are represented by an entry in the MIB-II interfaces table and supported by the DS1 MIB.

B-2

May 2002

8700-A2-GB20-40

Page 140
Image 140
Paradyne 8779, U8777 manual WarmStart, AuthenticationFailure, LinkUp and linkDown, Snmp Trap Description Possible Cause