3. Initial Startup and Configuration

Procedure

To enter Change Identity screen information:

1.Position the cursor in the System Name field. Enter a name unique in your network to identify the SNMP managed node (or unit)

2.Position the cursor in the System Location field. Enter the physical location of the unit.

3.Position the cursor in the System Contact field. Enter the name and contact information for the person responsible for the unit.

4.Press Ctrl-a to switch to the function key and message area below the dotted line.

5.Select Save and press Enter. Command Complete appears.

Configuring the Unit

Configuration option settings determine how the termination unit operates. Use the Configuration branch menu to display or change configuration option settings.

Configuration Options

he termination unit is shipped with factory settings in the Default Factory Configuration area. You can find default information by:

TReferring to Appendix A, Configuration Options.

Accessing the Configuration branch of the termination unit’s menu.

The termination unit has two sets of configuration option settings.

Configuration Option Area

Configuration Option Set

 

 

Current Configuration

The unit’s currently active set of configuration options.

 

 

Default Factory Configuration

A read-only configuration area containing the factory

 

default configuration options.

 

 

The Current Configuration matches the Default Factory Configuration until modified and saved by the user. If the factory default settings do not support your network’s configuration, you can customize the configuration options for your application.

8700-A2-GB20-40

May 2002

3-3